Number of Stops : Up to 64 stops
Drive Type : Rope
VVVF (with ADrive VVVF inverter)
Geared Machine
Gearless Machine (with or without machine room)
Lift Speed : Up to 4 m/s
Control Type : Full collective
Up or Down Collective
Group Command : Up to 8 elevators

SYSTEM FEATURES

Communication with Car Units
Serial car communication via CANBus
One to one connection by flexible cables with sockets between control panel and inspection box
Plug & play connection by one cable with socket between COP and inspection box
Communication with Landing Units
Serial landing communication via CANBus or Paralel landing communication via SP16 board.
CANBus line that is joined by cables with sockets from floor to floor and that extends along the shaft
Plug & play connection for landing operation panels by cables with sockets that are connected to shaft CANBus line at each floor
Door Contacts Wiring
Door contact installation that is joined by cables with sockets from floor to floor and that extends along the shaft
Connection for landing doors plug & play contacts by cables with sockets that are connected to door contact installation
Shaft Wiring
Connection to pit box by one cable with sockets
Car Positioning
By encoder
By magnetic switches and magnets
Automatic Door Control
Automatic Door Control for any type of door
Independent door control for each floor by double door support
1 door control input/output in inspection box, 2 in control panel
Indicator Options for Car Operating Panel:
5.7" 320x240 pixel color TFT LCD indicator
240 x 128 pixels graphic LCD indicator
128 x 64 pixels graphic LCD indicator (vertical / horizontal)
2 x 30 mm dot matrix display
3 x 30 mm dot matrix display
Call / Indicator Module Options for Landing Operation Panels
240 x 128 pixels graphic LCD indicator (over door)
128 x 64 pixels graphic LCD indicator (vertical)
2 x 30 mm dot matrix display
3 x 30 mm dot matrix display
Call module without display
Evacuation operation
By using a monophase 220VAC UPS or battery
To the nearest or specific floor
Door Bridging
Door pre-opening and door open re-leveling by door bridging relays on DBR board
Motor Phase Protection
By in-built inputs / outputs on main board
Programmable Inputs/ Outputs
Free programmable inputs / outputs on Arcode, car boards and landing boards
Test Functions
Special test function to test the connections of car and landing button panels
Remote Control
Control of ARL-500 main board and ADrive VVVF inverter by hand terminal that is connected to the CANBus line from any point
Safety Circuit Connections:
Special connections in control panel, inspection box and pit box for safety circuits
Car and shaft supply
Earth fault protected fuses for car and shaft lights
Shaft light circuit
Shaft light circuit via current pulse relay (activated with buttons in inspection box and pit box)
Emergency alarm
Emergency alarm siren (activated with buttons in inspection box and pit box)
Compatibility
EMC tested and verified
Full conpatibility to EN 81-20 as a complete elevator control system